Installation
The diagram below shows the connection between an EFOP fan-out-panel and 8
emergency phones and 8 analogue exchange lines.
3
1
PSTN
1
3
1 PSTN 3
2
4
2 PSTN 4
4
PSTN
2
Fig. 68
Connection of EFOP fan-out-panel (example)
The patch cables are available separately in lengths of 1 and 2 m (see "Equipment
Overview", page 254).
The internal wiring of the 3 right-hand connection blocks is the same as for the FOP
fan-out-panel (see Tab. 73).
Power supply
The EFOP fan-out-panel needs its own power supply and is powered by the supplied
power supply unit FSP065 via one of the two equivalent supply sockets. The power
supply unit is connected to the mains using a two-pin standard power cable.
Input values EFOP fan-out-panel 19 VDC / 0.5 A
In redundancy operation of the communication server a power supply unit of the same
type can also be connected to the second supply socket. The power supply unit is
available separately (see "Equipment Overview", page 254).
154
7
5
PSTN
FXS 1-4
1
3
1 PSTN 3
1
2
3
4
FXO 1-4
2
4
2 PSTN 4
8
PSTN
6
1
2
FXS 1-4
1
3
5
1
2
3
4
FXO 1-4
2
4
6
3
5
7
9 -12
4
6
8
13-16
syd-0585/1.2 – R4.1 – 08.2016
EFOP
7
1-4
1
3
8
5-8
2
4
1
3
5
7
9 -12
2
4
6
8
13-16
Mitel 470 as of R4.1