Operation and Maintenance
Destination alarm server (ATAS)
Event messages can also be sent via the ATAS interface, for instance, to an alarm
server. This may be an Mitel Alarm Server or a third-party alarm server. The use of the
ATAS protocol is subject to a licence.
After a first-start of the communication server, the signal destination
(ATAS)
is automatically allocated event table 6. The notification service via the ATAS
interface to the alarm server can be globally switched on or off.
SRM destination
Event messages can also be sent to the SRM server. Depending on the severity level
in the SRM agent, this changes the system status on the corresponding communica-
tion server line. The line colour changes at the same time. If the corresponding positive
event message arrives later or if the event message is confirmed in WebAdmin, the
status and colour are restored again. The following system statuses are defined:
Normal
(Blue colour):
No active event messages with the severity level
Serious
(Yellow colour):
At least one event message is available and needs to be closely examined. (Exam-
ple:
Charge counter
Critical
(Red colour)
At least one event message is available and is hampering the system's function.
(Example:
Fan
failure)
Note:
Not all negative event messages have a positive match. In this case, the event messages must
be confirmed manually in WebAdmin.
Event messages, which are not
of individual event messages is given in the Tab. 99 table.
Example:
Power output: There are no serious or critical event messages. The communication
server line in the SRM agent is blue and the system status is on Normal.
1. The event message
→ The communication server's system status in the SRM agent changes to Serious,
and the destinations turn yellow.
2. The event message
→ The communication server's system status in the SRM agent changes to Critical,
and the destinations turn red.
3. The event message
tive event messages view
244
overflow)
Serious
or Critical, are not sent to the SRM server. The severity
Charge counter overflow
Fan failure
reaches the SRM server.
Charge counter overflow
(
=mr).
Serious
or
Critical
reaches the SRM server.
is confirmed in WebAdmin in the
syd-0585/1.2 – R4.1 – 08.2016
Alarm server
is available.
Ac-
Mitel 470 as of R4.1