Interface
Terminal type
FXS
External equipment can be switched via control outputs
FXS
External switches for controlling internal switch groups via
control inputs
FXS
General bell
1) Maximum 64 radio units per location area
2) Operation on 2 DSI interfaces in each case
3) Maximum of 2 simultaneous call connections.
4) Transmission with the T.38 protocol is recommended for Fax over IP. The corresponding media resources
need to be allocated.
3. 4. 4
Terminal and network interfaces
Tab. 33
Terminal and network interfaces
Max. number...
Ethernet interfaces
Network interfaces, total (FXO, BRI-T, PRI, BRI-S
Terminal interfaces, total (DSI, FXS, BRI-S)
DSI terminal interfaces
Analogue terminal interfaces FXS
BRI-S terminal interfaces
Analogue network interfaces FXO
Basic rate interfaces BRI-T
Basic accesses BRI-S
ext.
Primary rate interfaces PRI
SIP access
2)
SIP access channels
1) 30 B channels per PRI network interface, of which 10 B channels each can be used without licence.
2) Licences required
3. 4. 5
Software assurance
Software Assurance (SWA) is Mitel's comprehensive support offer which gives access
to new software releases, support services and SRM remote access to the communi-
cation server.
The software assurance agreement has a fixed runtime and defines the number of au-
thorised users on the communication system. You can see at a glance whether a valid
Mitel 470 as of R4.1
syd-0585/1.2 – R4.1 – 08.2016
Terminal
)
ext.
1)
Expansion Stages and System Capacity
per
Mitel 470
228
228
per AIN with
per inter-
Mitel 470 as
Master
600
600
1
1 per node
AIN with
Mitel 470
Mitel 470 as
Master
3
per node
56
288
228
600
224
600
228
600
28
224
64
64
56
256
28
256
14
32
10
10
240
240
face
69