Installation
Mains power 1
EFOP
Fig. 69
Connection of an EFOP fan-out-panel
Tips
– Use the same mains socket to connect the power supply of the communication server and
the power supply of the EFOP fan-out-panel to the mains power. This prevents an unwanted
switchover in the event of a mains failure on the EFOP fan-out-panel only.
– In redundancy operation, connect the communication server and the APS2 auxiliary power
supply unit to separately protected mains power. This will further enhance the system's
operating reliability.
4. 7. 6
Ethernet interfaces
The communication server Mitel 470 has a Gbit Ethernet switch on the call manager
card. Three LAN interfaces are routed to the front panel of the call manager card and
labelled accordingly. The RJ45 sockets are highlighted in colour in the figure below.
156
Power supply 1
Copper wire yellow/ green
2,5 mm
4,0 mm
Power supply 2 (for power
supply redundancy only)
2
protected
2
unprotected
syd-0585/1.2 – R4.1 – 08.2016
Mains power 2
To the earth
connection
Stranded copper
yellow/ green
2
4,0 mm
unprotected
To the
communica-
tion server
Mitel 470 as of R4.1