Ethernet Interfaces - Mitel Aastra 470 System Manual

R3.2
Hide thumbs Also See for Aastra 470:
Table of Contents

Advertisement

Installation
4. 7. 6

Ethernet interfaces

The communication server Aastra 470 has a Gbit Ethernet switch on the call man-
ager card. Three LAN interfaces are routed to the front panel of the call manager
card and labelled accordingly. The RJ45 sockets are highlighted in colour in the fig-
ure below.
Fig. 70
Connection possibilities for Ethernet interfaces
Note
Circuit type as per EN/IEC 60950: SELV
Socket
Tab. 75
Connection of Ethernet interfaces
RJ45 socket
Settings
The IP address can either be taken from a DHCP server in the IP network or config-
ured statically. If a DNS server is used, the communication server can also be ad-
dressed via its host name.
Tab. 76
Default values, IP address
Parameter
IP address
Subnet mask
Gateway
DHCP
Host name
1)
This entry is hidden and does not appear in the parameter's input field
160
Pin
Signal
1
TX D1+
2
TX D1–
3
RX D2+
4
BI D3+
5
BI D3–
6
RX D2–
7
BI D4+
8
BI D4–
Parameter value
192.168.104.13
255.255.255.0
0.0.0.0
yes
<Model name>-<MAC-Address>
Example: Aastra430-00085d803100
1)
Aastra 470 as of R3.2
syd-0337/1.6 – R3.2 – 09.2014