HEIDENHAIN TNC 410 M Technical Manual page 90

Inverter systems and motors
Hide thumbs Also See for TNC 410 M:
Table of Contents

Advertisement

April 2007
Specifications,
regenerative power
supply units
Power supply
DC-link power
Rated power
a
Peak power
b
Peak power
Power loss
DC-link voltage
Current consumption
*1
15 V
*1
24 V
Current load
*1
15 V
*1
24 V
Load capacity +5 V
Degree of protection
Module width
Weight
ID
Accessories
Connection overview
Connection
Dimensions
a. 40% cyclic duration factor for duration of 10 minutes (S6-40%)
b. 4 s cyclic duration factor for duration of 20 s
c. After making your selection, check the current consumption of the
*1
15 V
and the 24 V
See page 2 – 54.
Modular Inverter
UVR 160 D
Air cooling
3 x 400 V~ ± 10%
(50 Hz to 60 Hz)
80 kW
110 kW
160 kW
c
400 mA
1.2 A
3.5 A
4.0 A
29 A
250 mm
Approx. 25.0 kg
530 341-xx
- - -
Page 6–15
Page 4–30, Page 6–59
Page 6–89
*1
supply of the entire modular inverter system.
UVR 160 DW
Water cooling
3 x 400 V~ ± 10%
(50 Hz to 60 Hz)
80 kW
110 kW
160 kW
Approx. 930 W
650 V–
400 mA
0.2 A
3.5 A
4.0 A
29A
IP 20
200 mm
Approx. 20.0 kg
560 106-xx
- - -
Page 6–14
Page 6–88
2 – 41

Advertisement

Table of Contents
loading

This manual is also suitable for:

Itnc 530Tnc 430 m

Table of Contents