Specifications, nonregenerative
compact inverters
Power supply
DC-link voltage
DC-link power
Rated power
a
Peak power
b
Peak power
Power loss
Rated current at a PWM frequency of
3333 Hz
4000 Hz
5000 Hz
6666 Hz
8000 Hz
10000 Hz
c
Current for S6-40%
frequency of
3333 Hz
4000 Hz
5000 Hz
6666 Hz
8000 Hz
10000 Hz
d
Maximum current
at a PWM
frequency of
3333 Hz
4000 Hz
5000 Hz
6666 Hz
8000 Hz
10000 Hz
Integral braking resistor
Load capacity +5 V
Degree of protection
Weight
ID
a. 40% cyclic duration factor for duty cycle time of 10 minutes (S6-40%)
b. 4 s cyclic duration factor for duty cycle time of 20 s
c. Spindle: 40% cyclic duration factor for duty cycle time of 10 minutes (S6-40%)
d. Axes: 0.2 s cyclic duration factor for duty cycle time of 10 s with 70% rated current preload
Spindle: 10 s cyclic duration factor for duty cycle time of 60 s with 70% rated current
preload
e. 1st value: Continuous power
2nd value: 1.5% cyclic duration factor for duty cycle time of 120 s
1 – 10
at a PWM
e
HEIDENHAIN Technical Manual for Inverter Systems and Motors
UE 212D
3 axes
1 axis
3 x 400 V~ ± 10% (50 Hz to 60 Hz)
565 V– (with supply voltage of 400 V)
15 kW
23 kW
40 kW
Approx. 595 W
9.0 A
18.0 A
8.3 A
16.5 A
7.5 A
15.0 A
6.3 A
12.6 A
5.5 A
11.0 A
4.6 A
9.1 A
18.0 A
36.0 A
16.5 A
33.0 A
15.0 A
30.0 A
12.6 A
25.2 A
11.0 A
21.9 A
9.1 A
18.3 A
1 kW / 27 kW
16 A
IP 20
Approx. 20 kg
558 304-xx
Spindle/axis
24.0 A/18.0 A
22.0 A/16.5 A
20.0 A/15.0 A
16.8 A/12.6 A
14.6 A/11.0 A
12.2 A/9.1 A
36.0 A / - -
33.0 A / - -
30.0 A / - -
25.2 A / - -
21.9 A / - -
18.3 A / - -
36.0 A
33.0 A
30.0 A
25.2 A
21.9 A
18.3 A