Specifications
Rated power
Peak power S6-40%
Peak power S6-20%
Peak power
Max. leakage current
Current consumption
24 V
Integral cooling
Degree of protection
Weight
ID
a. 40% cyclic duration factor for duty cycle time of 10 minutes (S6-40%)
b. 20% cyclic duration factor for duty cycle time of 10 minutes (S6-20%)
c. 4 s cyclic duration factor for duty cycle time of 20 s
d. After making your selection, check the current consumption of the 15 V
supply of the entire modular inverter system. See page 2 – 54.
April 2008
ZKF 140 dc-link filter
The ZKF 140 must be connected with the UVR 1xxD supply unit via the X79
unit bus. When choosing the ZKF, ensure that its rated power is at least as
high as the connected torque or linear motors.
d
Update Information No. 7
ZKF 140
80 kW
a
110 kW
b
140 kW
c
160 kW
< 6.0 A
440 mA
Yes
IP 20
Approx. 15 kg
597 954-01
*1
*1
and the 24 V
1 – 7