6.6 Connecting the UP 110 Braking Resistor Module

X79: Unit bus
6 – 66
The UP 110 braking resistor module must be used when axis motors without
brakes are used. In the event of power failure, it dissipates the energy
returned by the axis motors to the dc link. The UP 110 is switched on when
the inverter voltage U
falls below 720 V.
Danger
Danger of electrical shock!
The UP 110 braking resistor module may be opened only by HEIDENHAIN
service engineers.
Do not engage or disengage any terminals while they are under power.
Connection:
40-pin ribbon
Assignment
connector
1a to 3b
0 V
4a
+24 V
4b
+24 V
5a
+15 V
5b
+24 V
6a
+15 V
6b
+15 V
7a to 8b
Do not assign
9a
Reserved (SDA)
9b
Do not assign
10a
Reserved (SCL)
10b
ERR.TEMP
11a
PF.PS
11b
0 V
12a
RES.PS
12b
0 V
13a
PWR.OFF
13b
0 V
14a
5 V FS (spindle enable)
14b
0 V
15a
5 V FA (axis enable)
15b to 16b
0 V
17a and 17b
–15 V
18a and 18b
+15 V
19a to 20b
+5 V
Danger
The interface complies with the requirements of IEC 61800-5-1 for low
voltage electrical separation (except for 1a to 6b).
HEIDENHAIN Technical Manual for Inverter Systems and Motors
exceeds 740 V and is switched off again as soon as it
Z
*1
*1
*1
*1
*1
*1
*1
These voltages must not be
linked with other voltages (only
basic insulation)!