Connecting The Um 1Xx(B)(D) Power Modules; Unit Bus - HEIDENHAIN TNC 410 M Technical Manual

Inverter systems and motors
Hide thumbs Also See for TNC 410 M:
Table of Contents

Advertisement

6.7.2 Unit Bus

X79: Unit bus
April 2007
Connection:
40-pin ribbon
Assignment
connector
1a to 3b
0 V
4a
+24 V
4b
+24 V
5a
+15 V
5b
+24 V
6a
+15 V
6b
+15 V
7a to 8b
Do not assign
9a
Reserved (SDA)
9b
Do not assign
10a
Reserved (SCL)
10b
ERR.TEMP
11a
PF.PS
11b
0 V
12a
RES.PS
12b
0 V
13a
PWR.OFF
13b
0 V
14a
5 V FS (spindle
enable)
14b
0 V
15a
5 V FA (axis
enable)
15b to 16b
0 V
17a and 17b
–15 V
18a and 18b
+15 V
19a to 20b
+5 V
Danger
The interface complies with the requirements of IEC 61800-5-1 for low
voltage electrical separation (except for 1a to 6b).

Connecting the UM 1xx(B)(D) Power Modules

*1
*1
These voltages must
*1
not be linked with other voltages
*1
(only basic insulation)!
*1
*1
*1
6 – 69