UR 2xx(D)
X31: Power supply
April 2007
Connecting the UE 2xxB and UR 2xx(D) Compact Inverters
The inverter voltage U
The UR 2xx regenerative compact inverters must be connected to the main
power line via the KDR 120 commutating reactor and the line filter. This is
necessary for keeping the main line free of disruptive higher harmonics.
For power connection, see page 4 – 30.
Power supply
L1
L2
L3
PE
Tightening torque for
connecting terminals:
Note
The cables between the UR 2xx compact inverter and commutating reactor
as well as between the commutating reactor and line filter must be as short
as possible (< 0.4 m)!
is 650 V–.
Z
UR 2xx(D)
400 V~ ± 10%
50 Hz to 60 Hz
Cable / single conductor (HT wire):
2
10 mm
(AWG 6)
Single conductor H07 V2-K:
2
6 mm
(AWG 10)
Line fuse:
35 A (gR) Siemens Sitor type
Grounding terminal:
2
≥ 10 mm
(AWG 6)
0.7 Nm (6.5 - 7 lbs/in)
5 – 55