5.7 Connecting the UV 105 Power Supply Unit

X69, X169: NC
supply voltage and
control signals
X74: 5-V connection
of the UV 105
April 2007
Note
For the control to be able to evaluate the status signals of the power supply
units, connector X69 of the controller unit must be connected by ribbon
cable with X69 of the UV 105.
Since non-HEIDENHAIN inverters do not send any status signals, an
adapter connector (Id. Nr. 349 211-01) must be connected to X69 on the
UV 105. This connector is delivered with the UV 105.
Connection:
50-pin ribbon
Assignment
connector
1a to 5b
+5 V
6a to 7b
+12 V
8a
+5 V (low-voltage
separation)
8b
0 V (low-voltage
separation)
9a
+15 V
9b
–15 V
10a
UZAN
10b
0 V
11a
IZAN
11b
0 V
12a
RES.PS
12b
0 V
13a
PF.PS.ZK
13b
GND
14a
ERR.UZ.GR
14b
GND
15a
ERR.IZ.GR
15b
GND
16a
ERR.TMP
Connection:
Wire color of 5-V connection
Black
Red
Connecting the UV 105 Power Supply Unit
50-pin ribbon
Assignment
connector
16b
GND
17a
RDY.PS
17b
GND
18a
ERR.ILEAK
18b
GND
19a
PF.PS.AC (only
UV 120, UV 140,
UV 150, UR 2xx)
19b
GND
20a
Do not assign
20b
GND
21a
Do not assign
21b
GND
22a
Do not assign
22b
GND
23a
Reserved (SDA)
23b
GND
24a
Reserved (SLC)
24b
GND
25a
RES.LE
25b
GND
5-V terminal on CC 42x
0 V
+5 V
5 – 65

Advertisement

Table of Contents
loading

This manual is also suitable for:

Itnc 530Tnc 430 m