5.1.19 Meaning of the LEDs

UE 1xx
LED
NC RESET
PWR FAIL
PWR RESET
READY
TEMP >>
U
>>
DC LINK
U
DC LINK ON
X 71 SP.
X 72 AXES
SH1 (RED)
RDY (GREEN)
SH2
5 – 22
On the front of the compact inverters are several LEDs for functional control,
with the following meaning:
Meaning
Reset signal from LE, CC to UE
U
too low, U
< 410 V (e.g. failure of a
Z
Z
phase under load, power < 290 V)
Reset signal from UE to LE, CC
Inverter ready
Temperature of heat sink too high (> 100
°C)
U
too high (> approx. 850 V); power
Z
modules are switched off
Main contactor on
Safety relay for spindle on
Safety relay for axes on
Safe stop 1; no enable from control (main
contactor not active, DSP error, PLC error
with Emergency Stop, hardware or
software error of LE, CC)
Axis/Spindle enabled
Safe stop 2; no drive enable from control
(e.g. by the PLC, active via external signal
or SH1)
HEIDENHAIN Technical Manual for Inverter Systems and Motors
Signal direction Signal
LE, CC → UE
RES.LE
UE → LE, CC
PF.PS
UE → LE, CC
RES.PS
UE → LE, CC
RDY
UE → LE, CC
ERR.TEMP
UE → LE, CC
ERR.UZ.GR
LE, CC → UE
SH1B
UE → LE, CC
RDY
LE, CC → UE
SH2