Main Contactor And Safety Relay - HEIDENHAIN TNC 410 M Technical Manual

Inverter systems and motors
Hide thumbs Also See for TNC 410 M:
Table of Contents

Advertisement

6.4.2 Main Contactor and Safety Relay

X70: Main
contactor
X71: Safety relay
for spindle
X72: Safety relay
for axes
6 – 54
Connection:
Connection
Terminal X70
1
2
3
4
5
a
6
a
7
a. Max. 125 V
Warning
A recovery diode is required in the proximity of inductive loads, e.g. relay or
contactor coils.
Connection:
Connecting
terminals
X71 and X72
1
2
3
4
5
a
6
a
7
a. Max. 125 V
Warning
A recovery diode is required in the proximity of inductive loads, e.g. relay or
contactor coils.
HEIDENHAIN Technical Manual for Inverter Systems and Motors
Assignment
+24 V output (max. 250 mA)
0 V
+24 V input for U
ON
Z
Do not assign
Do not assign
Normally closed contact (OE1)
Normally closed contact (OE2)
Assignment
+24 V output (max. 250 mA)
0 V
+24 V input for Axis ON, Spindle ON
Do not assign
Do not assign
Normally closed contact (OE1A or OE1S)
Normally closed contact (OE2A or OE2S)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Itnc 530Tnc 430 m

Table of Contents