5.2 Mounting and Connecting the Compact Inverter

5.2.1 UE 2xx Compact Inverter

Arranging the
modules
Connecting the
modules
5 – 30
If an LE 41x M "compact" (with internal PWM interfaces) is to be operated
with a UE 2xx compact inverter, the compact inverter is arranged next to the
left of the LE.
UE 2xx
If an LE 426M is to be operated with a compact inverter, the UV 102 power
supply module must be placed between the two modules.
UE 2xx
LE 41xM "compact": The compact inverter and LE are connected via ribbon
cables, which are connected with plug-in PCBs at the LE end. Once this
connection has been established, the protective cover (supplied as accessory
with LE) must still be screwed onto the LE and the compact inverter.
LE 426M: The front panel of the UV 102 must be removed. Then the compact
inverter and the UV 102 are connected to each other via ribbon cables, which
are connected with plug-in PCBs at the UV 102 end. The ribbon cables of the
UV 102 are connected to the LE. Once these connections have been made,
the front panel is replaced on the UV 102 housing.
HEIDENHAIN Technical Manual for Inverter Systems and Motors
LE 41x M "compact"
UV 102
LE 426 M

Advertisement