Mounting And Connection Of The Modular Inverter System - HEIDENHAIN TNC 410 M Technical Manual

Inverter systems and motors
Hide thumbs Also See for TNC 410 M:
Table of Contents

Advertisement

6.2 Mounting and Connection of the Modular Inverter System

Arranging
the modules
Connecting the
modules
Direct drives
6 – 48
The power modules are arranged between the power supply unit and the
control. The power module for the spindle is placed next to the power supply
unit, and the power modules for the axes are then placed in order of
decreasing rated current.
If the UP 110 braking resistor module is used together with the regenerative
power supply units, the braking resistor is arranged between the weakest
power module and the control.
The power module for a second spindle (not on all controls possible) is placed
between the power module for the first spindle and the strongest power
module for the axes.
For more examples of arranging the modules and connection overviews, Page
4–30.
UV(R)
UM
1x0(D)
1xx(B)(D)
for the
first
spindle
The dc-link power U
Z
unit via conductor bars (screwed onto each module, and if required, the
UP 110).
A further conductor bar establishes the ground connection between the
individual modules.
Three conductor bars are included as accessories with the power modules
(two for the dc-link, one for the ground).
A 50-line ribbon cable connects the control with the UV(R) 1x0 and supplies
the power to the control.
A 40-line ribbon cable connects the power supply unit with the power
modules, and if required with the UP 110, forming the unit bus.
The 20-line ribbon cables connect the control and the power modules, and
supply the PWM signals to the axes and the spindle(s).
Direct drives (linear motors, torque motors) used in conjunction with
regenerative inverter systems require a ZKF 1xx dc-link filter, which is
mounted to the left of the direct drives' power modules. The dc-link current is
then led through this filter.
HEIDENHAIN Technical Manual for Inverter Systems and Motors
UM
Opt.
1xx(B)(D)
ZKF 1xx
for the
second
spindle
(not on all
controls)
is supplied to the power modules by the power supply
UM
Opt.
1xx(B)(D)
UP 110
LE 41x M
"modular"
LE 426 M
LE 430 M
MC 422/
CC 42x

Advertisement