1.4 Accessories
March 2005
Designation
Designation
(new)
(old)
UM 122D
UM 122
a. As of mid-2005 (depending on software). Information available
from HEIDENHAIN.
New ZKF 110 dc-link filter for use with linear motors or torque motors
• Rated power: 30 kW
• Max. power during S6-20% cycle: 67 kW
• Max. leakage current < 1.3 A
New ZKF 120 dc-link filter for use with linear motors or torque motors
• Rated power: 30 kW
• Max. power during S6-20% cycle: 67 kW
• Max. leakage current < 6 A
• Modular design
New ZKF 130 dc-link filter for use with linear motors or torque motors
• Rated power: 55 kW
• Max. power during S6-20% cycle: 100 kW
• Max. leakage current< 6 A
• Modular design
• Integrated cooling (fan)
• Unit bus interface (X79)
New adapter module for coupling the power supply units
• Modular design
• Integration of the supply bus (X69) in the monitoring system
New KDR 130B commutating reactor
• Rated current: 3 x 40.5 A
• Thermally permissible continuous current: 3 x 45 A
Update Information No. 5
Improvement
Additional features for
diagnostic functions.
Higher rated current
values.
Higher maximum
a
current values.
Continuous load
at f
= 5 kHz
PWM
(axis/spindle)
2x 25 A/1x 34 A
(up to now
2x 23 A/
1x 31 A)
1 – 5