1.2 Compact Inverters
1.2.1 Non-Regenerative Compact Inverters
1.2.2 Regenerative Compact Inverters
1 – 2
New compact inverter UE 110, rated power output 10 kW
• Continuous load on axes (at f
• Continuous load on spindle (at f
New compact inverter UE 112, rated power output 10 kW
• Continuous load on axes (at f
• Continuous load on spindle (at f
The following compact inverters were improved:
Designation
Designation
(new)
(old)
UR 230D
UR 230
UR 240D
UR 240
UR 242D
UR 242
HEIDENHAIN Technical Manual for Inverter Systems and Motors
= 3.3 kHz): 3 x 6 A
PWM
= 3.3 kHz): 24 A
PWM
= 3.3 kHz): 3 x 6 A, 1 x 9 A
PWM
= 3.3 kHz): 24 A
PWM
Improvement
New, more powerful
power supply unit with
separate 5-V connection
on the front panel (X74).
Additional features for
diagnostic functions.
New, more powerful
power supply unit with
separate 5-V connection
on the front panel (X74).
Additional features for
diagnostic functions.
New, more powerful
power supply unit with
separate 5-V connection
on the front panel (X74).
Additional features for
diagnostic functions.
Rated power
output of
dc-link
22 kW
22 kW
22 kW