HEIDENHAIN TNC 410 M Technical Manual page 310

Inverter systems and motors
Hide thumbs Also See for TNC 410 M:
Table of Contents

Advertisement

Connecting
Assignment Connecting
terminal X89B
UE 21xB
1
Do not
assign
2
Do not
assign
Temperature
switch
X2: Fan for the
PW 1x0(B) external
braking resistor
5 – 62
Pin layout on UE 21xB for external braking resistor:
terminal X89A
UE 21x B
1
2
Warning
The internal and an external braking resistor must not be operated in
parallel!
Pin layout on UE 230B and UE 24xB:
Connecting
Assignment
terminal X89
UE 230B
UE 24xB
1
+U
Z
2
Switch against
–U
Z
The temperature switch is a normally closed contact and is set to protect the
braking resistor from being damaged. It can have a maximum load of 250 V,
5 A. The switch can be connected to a PLC input on the control and evaluated
via the PLC.
Connection:
Connecting terminal on PW 21x
T1
T2
Connecting terminal X3 on the
PW 110B
1
2
Connection:
Connecting terminal X2
+
HEIDENHAIN Technical Manual for Inverter Systems and Motors
Assignment
PW 21x
+U
RB 1
Z
Switch against –U
RB 2
Z
PW 21x
RB 1
RB 2
Assignment
1
2
Assignment
1
2
Assignment
+24 V (PLC)
0 V
PW 1x0(B);
connecting
terminal X1
1
2
PW 1x0(B),
connecting
terminal X1
1
2

Advertisement

Table of Contents
loading

This manual is also suitable for:

Itnc 530Tnc 430 m

Table of Contents