HEIDENHAIN TNC 410 M Technical Manual page 436

Inverter systems and motors
Hide thumbs Also See for TNC 410 M:
Table of Contents

Advertisement

Power cables for
HEIDENHAIN
asynchronous
motors
Type of
Cable
power
a
cable
1
352 956-xx (complete)
2
352 957-xx (complete)
3
348 949-03 (in meters)
4
348 949-04 (in meters)
5
348 949-05 (in meters)
6
348 949-06 (in meters)
7
352 958-xx (complete)
8
352 959-xx (complete)
9
348 949-07 (in meters)
10
348 949-09 (in meters)
1
10
348 949-09 (in meters)
a. The assignment of the cables to the motors is shown in the table
"Asynchronous Motors, QAN Series" on page 8.
b. For frequent flexing.
c. The following cable lengths are available:
5 m: xx = 05
7 m: xx = 07
10 m: xx = 10
12 m: xx = 12
15 m: xx = 15
7 – 14
The following cables are available from HEIDENHAIN for connecting the
asynchronous motors:
Note
All cables have a UL certification and are suited for use at ambient
temperatures of up to 40 °C.
The conductor material consists of copper (Cu).
Type of
cable
c
4 x 4 mm
c
4 x 6 mm
4 x 2.5 mm
4 x 4 mm
4 x 6 mm
4 x 10 mm
c
4 x 16 mm
c
4 x 25 mm
4 x 16 mm
4 x 35 mm
4 x 35 mm
HEIDENHAIN Technical Manual for Inverter Systems and Motors
Diameter
Max.
bending
radius
2
≥ 75 mm
13.7 mm
2
≥ 85 mm
15.1 mm
2
≥ 65 mm
12.1 mm
2
≥ 75 mm
14.1 mm
2
≥ 85 mm
15.6 mm
2
≥ 105 mm
20.9 mm
2
≥ 135 mm
26.5 mm
2
≥ 150 mm
30.5 mm
2
≥ 135 mm
27.3 mm
2
≥ 175 mm
35.5 mm
2
≥ 175 mm
35.5 mm
Type of
installation
b
B2
B2
B2
B2
B2
B2
B2
B2
B2
B2
C and E

Advertisement

Table of Contents
loading

This manual is also suitable for:

Itnc 530Tnc 430 m