2.2 Overview of Inverter Systems

2.2.1 Non-Regenerative Compact Inverters

2.2.2 Regenerative Compact Inverters

April 2007
Overview of non-
regenerative
compact inverters
UE 110 – (page 2 – 11)
UE 112 – (page 2 – 11)
UE 210 – (page 2 – 14)
UE 212 – (page 2 – 14)
UE 230 – (page 2 – 14)
UE 240 – (page 2 – 14)
UE 242 – (page 2 – 14)
UE 210B – (page 2 – 16) 4
UE 211B – (page 2 – 16) 4
UE 212B – (page 2 – 17) 5
UE 230B – (page 2 – 17) 3
UE 240B – (page 2 – 18) 4
UE 242B – (page 2 – 18) 5
a. Data for a PWM frequency of 3.33 kHz
Overview of regenerative
compact inverters
UR 230 – (page 2 – 21)
UR 230D – (page 2 – 21)
UR 240 – (page 2 – 22)
UR 240D – (page 2 – 22)
UR 242 – (page 2 – 23)
UR 242D – (page 2 – 24)
a. Depending on setting of operating mode switch (axis/spindle)
b. Data for a PWM frequency of 5 kHz
Overview of Inverter Systems
Axis
Axis current
number
(in A)
at 5 kHz
a
3 +
6
spindle
a
4 +
6 / 9
spindle
3
7.5
4
7.5 / 14
2
7.5
3
7.5
4
7.5 / 23
7.5 / 15
7.5 / 15 / 15
7.5 / 15 / 15
7.5 / 23
7.5 / 23
7.5 / 23 / 23
Axis
Axis current
a
b
number
(in A)
2 / 1
7.5 / 25
2 / 1
7.5 / 25
3 / 1
7.5 / 25
3 / 1
7.5 / 25
3 / 1 / 1
7.5 / 25 / 25
3 / 1 / 1
7.5 / 25 / 25
Spindle
Rated
(in A)
power
at 5 kHz
a
24
10 kW
a
24
10 kW
19
13 kW
19
13 kW
31
20 kW
31
20 kW
31
20 kW
20
15 kW
20
15 kW
20
15 kW
31
22 kW
31
22 kW
31
22 kW
Spindle
Rated
1/2/3
power
b
(in A)
35 / – / –
22 kW
35 / – / –
22 kW
10 / 35 / – 22 kW
10 / 35 / – 22 kW
10 / 35 / 35 22 kW
10 / 35 / 35 22 kW