Line Filters - HEIDENHAIN TNC 410 M Technical Manual

Inverter systems and motors
Hide thumbs Also See for TNC 410 M:
Table of Contents

Advertisement

2.5.3 Line Filters

2 – 70
If you are using regenerative inverter systems, you must use a line filter in
addition to the commutating reactor. Line filters suppress interference and
ensure EMC-compatible energy recovery. The line filter must be connected
between the power line and the commutating reactor.
The size of the line filter depends on the power module used.
EPCOS 3 line filter5 A
Specifications
suitable for
Rated voltage
Rated frequency
Rated current
Power loss
Degree of protection
Weight
ID
Connection
Specifications
suitable for
Rated voltage
Rated frequency
Rated current
Power loss
Degree of protection
Weight
ID
Connection
a. With integrated three-phase capacitor
HEIDENHAIN Technical Manual for Inverter Systems and Motors
EPCOS 12 line filter0 A
EPCOS 35 A line filter
UR 2xx(D), UV 120,
UVR 120 D
3 x 400 V
50 Hz/60 Hz
3 x 35 A
Approx. 50 W
IP 20
5 kg
340 691-01
Page 4–30
Line Filters
a
EPCOS 120 A
UVR 160D(W)
3 x 400 V
50 Hz/60 Hz
3 x 120 A
Approx. 115 W
IP 20
13.5 kg
575 292-01
Page 4–30
EPCOS 80 A line filter
UV 140, UVR 150,
UVR 130 D, UVR 140 D,
UVR 150 D
3 x 400 V
50 Hz/60 Hz
3 x 80 A
Approx. 75 W
IP 20
11 kg
340 651-01

Advertisement