5.5 Connecting the UE 2xxB and UR 2xx(D) Compact Inverters
5.5.1 Power Supplies
UE 2xxB
X31: Power supply
5 – 54
Danger
Danger of electrical shock!
The compact inverters may be opened only by HEIDENHAIN service
engineers.
Do not engage or disengage any terminals while they are under power.
Danger
IEC 61800-5-1 requires a non-detachable connection to the line power
supply.
Note
If the power supply is other than 400 V, an autotransformer is required. It
must comply at least with the connection specifications of the subsequent
compact inverter.
With a power supply of 400 V, the inverter voltage U
For power connection, see page 4 – 31.
Connecting
UE 21x B
terminals
L1
400 V~ ± 10%
50 Hz to 60 Hz
L2
L3
Cable / single conductor
(HT wire):
6 mm
Single conductor H07 V2-K:
4 mm
Line fuse:
35 A (gR) Siemens Sitor
type
Grounding terminal:
≥ 10 mm
Tightening torque
0.7 Nm
for connecting
(6.5 – 7 lbs/in)
terminals
HEIDENHAIN Technical Manual for Inverter Systems and Motors
2
(AWG 10)
2
(AWG 10)
2
(AWG 6)
is 565 V–.
Z
UE 230 B, UE 24xB
400 V~ ± 10%
50 Hz to 60 Hz
Cable / single conductor
(HT wire):
2
10 mm
(AWG 6)
Single conductor H07 V2-K:
2
6 mm
(AWG 10)
Line fuse:
50 A (gR) Siemens Sitor
type
Grounding terminal:
2
≥ 10 mm
(AWG 6)
2.0 – 2.3 Nm
(18 – 20.5 lbs/in)