6.1.16 UM 111B Power Module
April 2007
Danger
Do not engage or disengage any connecting elements while the unit is
under power!
X112
X112
X79
Sliding switch:
X344
X392
X82
Connection Overview
PWM, axis / spindle
PWM, axis/spindle
(The upper or lower X112 may be used;
Internally both of these inputs are switched in parallel.)
Unit bus
AXIS: Axis module
Enabling through X72 of the power supply unit
SPINDLE: Spindle module
Enabling through X71 of the power supply unit
24-V supply for motor holding brake
(available as of version 336 948-03)
Motor holding brake
(available as of version 336 948-03)
Motor connection for axis / spindle
Equipment ground
6 – 29