6.4.3 X90: 24-V Output (Only UV 130)

6.4.4 NC Supply Voltage and Control Signals

X69: NC supply
voltage and control
signals
April 2007
Connection:
Connecting
terminal X90
+
For lengths of 600 mm and longer, the 50-line ribbon cable for the NC power
supply and control signals is led doubled to the control in order to increase the
wire cross section.
50-pin ribbon
Assignment
connector
1a to 5b
+5 V
6a to 7b
+12 V
8a
+5 V (low-voltage
separation)
8b
0 V (low-voltage
separation)
9a
+15 V
9b
–15 V
10a
UZAN
10b
0 V
11a
IZAN
11b
0 V
12a
RES.PS
12b
0 V
13a
PF.PS
13b
GND
14a
ERR.UZ.GR
14b
GND
15a
ERR.IZ.GR
15b
GND
16a
ERR.TEMP
(UV, ZKF, UP)
Danger
The interface complies with the requirements of IEC 61800-5-1 for "low
voltage electrical separation."
Connecting the UV 130(D) Power Supply Unit
Assignment
+24 V (max. 250 mA)
0 V
50-pin ribbon
connector
16b
17a
17b
18a
18b
19a
19b
20a
20b
21a
21b
22a
22b
23a
23b
24a
24b
25a
25b
Assignment
GND
RDY.PS
GND
ERR.ILEAK
GND
Do not assign
GND
Do not assign
GND
0 V
GND
0 V
GND
Reserved (SDA)
GND
Reserved (SCL)
GND
RES.LE
GND