Procedure Title:
LD6 Operations Manual (B Variant)
File Ref.:
AB-V-MA-00589
4.2

POWER FAULTS

Fault
Reason
Shutdown has been
activated from Action
menu but the power
switch in on
External supply fault,
disconnected or
switched off
Fault in AC/DC supply. Disconnect the power supply. Check voltages
Screen
blank
LD6 fault.
Screen brightness
turned down
Rev No:
A4
Remedy
Toggle the power switch. This will reboot the unit and the
MMI should appear.
Check power to the LD6. Adjust screen brightness using
the control on the left side of the LD6.
Check power connections to the unit for physical and
electrical integrity.
to and from unit. The LD6 AC is 110/240 V. DC power 12–
24 VDC.
Reconnect power and allow LD6 to restart.
If the PSU voltage is correct contact the
VERIPOS Helpdesk.
Use the brightness control knob to increase screen
brightness.