Procedure Title:
LD6 Operations Manual (B Variant)
File Ref.:
AB-V-MA-00589
2.9.3.4 External RTCM Inputs
As detailed in Section 2.9.3.2, it is possible to input RTCM correction data to the LD6 from
external sources.
It is possible to configure up to two Ext RTCM inputs. Only one RTCM data source will be
used at any one time. Each data source will be designated with a priority level. The priority
for VERIPOS RTCM corrections are as follows:
1. RTCMa (LD6 L-Band)
2. Ext RTCM 1
3. Ext RTCM 2
Any non-VERIPOS corrections available (e.g. on-board MF or UHF) will only be used in the
event that all VERIPOS correction sources have failed or are disabled.
The LD6 is only able to receive VERIPOS RTCM corrections from external devices through
serial connection, it will not use external 3

2.9.4 Network

Touch the Network button in the Settings menu to open the Network page.
Rev No:
A4
PRIMARY
SECONDARY
TERTIARY
rd
Party RTCM corrections.
Page 51