Veripos LD6 Operation Manual page 37

Hide thumbs Also See for LD6:
Table of Contents

Advertisement

Procedure Title:
LD6 Operations Manual (B Variant)
File Ref.:
AB-V-MA-00589
The RTCM entry shows the correction age in seconds. In normal use this will correct every
few seconds.
If the MF RTCM signal is lost the time will increment up to 300 seconds then show >300 s.
2.7.1.1 Module Info
Touch the arrow to display the MF module information.
This gives information on whether the MF receiver is in AUTOMATIC or MANUAL mode as
well as the serial and firmware numbers for the SBX-4 MF receiver card.
2.7.1.2 Channel
Touching the Channel arrow shows the Channel Monitor screen with information on the
channel selected – Station, Frequency, Bit rate, Signal strength (SS), Signal to noise ratio
(SNR) and Word error rate (WER).
A typical MF channel values range is shown in the screen above.
Stat:
Freq:
Rate:
SS:
SNR:
WER:
Rev No:
A4
Unique numerical ID number and name of station
Frequency of the received station
Data baud rate of the received transmission
The signal strength received in dB µV/m
The current signal to noise ratio in dB/Hz
The word error rate