User Manual of Thermal Network Speed dome
Reflective Temperature: If there is any target with high emissivity in the scene,
check the checkbox and set the reflective temperature to correct the
temperature. If no such target exists, uncheck the checkbox.
Tolerance Temperature: The device judges whether the triggered alarm stops
until the device temperature/temperature difference is lower than rule
temperature by tolerance temperature. E.g., set tolerance temperature as 3° C,
set alarm temperature as 55° C, and set pre-alarm temperature as 50° C. The
device sends pre-alarm when its temperature reaches 50° C and it alarms when
its temperature reaches 55° C and only when the device temperature is lower
than 52° C will the alarm be cancelled.
3) Set the alarm rules.
For Point Rule:
a) Click
to show the Alarm Rule setting interface.
b) Set the alarm rule.
c) Set the Alarm Temperature, Pre-Alarm Temperature, and Tolerance
Temperature.
E.g., select Alarm Rule as Average Temperature is Higher than, and set the
Alarm Temperature to 50 ° C, and the device alarms when its average
temperature is higher than 50 ° C.
For Line Rule:
a) Click
to show the Alarm Rule setting interface.