128
Camshaft
MIF1056A
The data given refer to the normal pin diameter (dimensions in mm)
The support journal surfaces on the shaft and cams
must be finely honed; if there are signs of seizing or
scoring, replace the shaft and relative bushings.
Checking Cam Lift and Pin Alignment
Set the shaft on tailstocks and, using a dial gauge
with a 1/100 mm scale placed on the central support,
check that the alignment error is no greater than 0.04
mm (0.0015 in); change the shaft if it is.
Check the diameter of the supporting pins of the
camshaft (2) with the micrometer (1) on two orthogo-
nal axes.
SECTION 10 - - ENGINE - - CHAPTER 1
.
.
Camshaft data
MIF1057A
276
277