6.3 List of MECHATROLINK-III Common Parameters

6.3

List of MECHATROLINK-III Common Parameters

The following table lists the common MECHATROLINK-III parameters. These common parame-
ters are used to make settings from the host controller via MECHATROLINK communications.
Do not change the settings with the Digital Operator or any other device.
Parameter
No.
01
PnA02
02
PnA04
03
PnA06
04
PnA08
05
PnA0A
06
PnA0C
07
PnA0E
08
PnA10
09
PnA12
0A
PnA14
0B
PnA16
0C
PnA18
6-46
Size
Name
Encoder Type Selec-
4
tion (read only)
0000 hex
Absolute encoder
0001 hex
Incremental encoder
Motor Type Selection
4
(read only)
0000 hex
Rotary Servomotor
0001 hex
Linear Servomotor
Semi-closed/Fully-
4
closed Selection
(read only)
0000 hex
Semi-closed
0001 hex
Fully-closed
Rated Motor Speed
4
(read only)
Maximum Output
4
Speed (read only)
Speed Multiplier
4
(read only)
Rated Torque
4
(read only)
Maximum Output
4
Torque (read only)
Torque Multiplier
4
(read only)
Resolution
4
(read only)
4
Scale Pitch
Pulses per Scale
4
Pitch (read only)
Setting Unit
Setting Range
[Resolution]
0 to 1
0 to 1
0 to 1
-1
0 to FFFFFFFF
1 min
-1
0 to FFFFFFFF
1 min
-1,073,741,823
to
1,073,741,823
0 to FFFFFFFF
1 Nm
0 to FFFFFFFF
1 Nm
-1,073,741,823
to
1,073,741,823
0 to FFFFFFFF
1 pulse/rev
1 nm
0 to 65,536,000
[0.01 μm]
1 pulse/
0 to FFFFFFFF
pitch
Default
Applicable
When
Setting
Motors
Enabled
All
All
All
All
All
All
All
All
All
Rotary
After
0
Linear
restart
Linear
Continued on next page.