Alarm Number:
Possible Cause
Alarm Name
A failure occurred in
the Safety Option
A.E74:
Module.
Unsupported
Safety Option
An unsupported
Module
Safety Option Module
was connected.
The delay between
activation of the
/HWBB1 and
A.Eb1:
/HWBB2 input sig-
Safety Function
nals for the HWBB
Signal Input Tim-
was ten second or
ing Error
longer.
A failure occurred in
the SERVOPACK.
A.EC8:
Gate Drive Error 1
(An error
occurred in the
gate drive circuit.) A failure occurred in
the SERVOPACK.
A.EC9:
Gate Drive Error 2
(An error
occurred in the
gate drive circuit.)
A timeout error
A.Ed1:
occurred for a
Command Exe-
MECHATROLINK
cution Timeout
command.
The three-phase
power supply wiring is
not correct.
The three-phase
power supply is
A.F10:
unbalanced.
Power Supply
Line Open Phase
A single-phase power
(The voltage was
supply was input with-
low for more than
out specifying a sig-
one second for
nal-phase AC power
phase R, S, or T
supply input (Pn00B =
when the main
n.1).
power supply
was ON.)
A failure occurred in
the SERVOPACK.
Confirmation
Replace the Safety Option
Module.
Refer to the catalog of the
Connect a compatible
connected Safety Option
Safety Option Module.
Module.
The output signal circuits
or devices for /HWBB1
and /HWBB2 or the SER-
VOPACK input signal cir-
Measure the time delay
cuits may be faulty.
between the /HWBB1 and
Alternatively, the input sig-
/HWBB2 signals.
nal cables may be discon-
nected. Check to see if
any of these items are
faulty or have been dis-
connected.
Replace the SERVO-
PACK.
Turn the power supply to
the SERVOPACK OFF and
ON again. If an alarm still
occurs, the SERVOPACK
may be faulty. Replace the
SERVOPACK.
Execute the SV_ON or
Check the motor status
SENS_ON command only
when the command is
when the motor is not
executed.
operating.
• For fully-closed loop
control, check the sta-
tus of the external
Execute the SENS_ON
encoder when the com-
command only when an
mand is executed.
external encoder (e.g., a
• For other types of con-
linear encoder) is con-
trol, check the status of
nected.
the linear encoder when
the command is exe-
cuted.
Check the power supply
Make sure that the power
wiring.
supply is correctly wired.
Measure the voltage for
Balance the power sup-
each phase of the three-
ply by changing phases.
phase power supply.
Check the power supply
Match the parameter set-
and the parameter set-
ting to the power supply.
ting.
Turn the power supply to
the SERVOPACK OFF and
ON again. If an alarm still
occurs, the SERVOPACK
may be faulty. Replace the
SERVOPACK.
5.3 Troubleshooting Alarms
Continued from previous page.
Refer-
Correction
ence
*1
*1
Continued on next page.
5
5-35

Advertisement

Table of Contents
loading

Table of Contents