YASKAWA SGD7S-***A20****F62 Series Product Manual page 172

Sigma-7-series ac servo drive, sigma-7s servopack with ft/ex specification for transfer and alignment application
Table of Contents

Advertisement

6.2 List of Servo Parameters
Parameter
No.
Pn861
*8
M3
Pn862
*8
M3
Pn863
*8
M3
6-42
Name
SVCMD_IO Input Signal
2
Monitor Allocations 2
Input Signal Monitor Allocation for CN1-8 (SVCMD_IO)

n.
X
0 to 7 The settings are the same as the CN1-13 allocations.
CN1-8 Input Signal Monitor Enable/Disable Selection

n.
X
0
Disable allocation for CN1-8 input signal monitor.
1
Enable allocation for CN1-8 input signal monitor.
Input Signal Monitor Allocation for CN1-9 (SVCMD_IO)

n.
X
0 to 7 The settings are the same as the CN1-13 allocations.
CN1-9 Input Signal Monitor Enable/Disable Selection

n.X
0
Disable allocation for CN1-9 input signal monitor.
1
Enable allocation for CN1-9 input signal monitor.
SVCMD_IO Input Signal
2
Monitor Allocations 3
Input Signal Monitor Allocation for CN1-10 (SVCMD_IO)

n.
X
0 to 7 The settings are the same as the CN1-13 allocations.
CN1-10 Input Signal Monitor Enable/Disable Selection

n.
X
0
Disable allocation for CN1-10 input signal monitor.
1
Enable allocation for CN1-10 input signal monitor.
Input Signal Monitor Allocation for CN1-11 (SVCMD_IO)

n.
X
0 to 7 The settings are the same as the CN1-13 allocations.
CN1-11 Input Signal Monitor Enable/Disable Selection

n.X
0
Disable allocation for CN1-11 input signal monitor.
1
Enable allocation for CN1-11 input signal monitor.
SVCMD_IO Input Signal
2
Monitor Allocations 4
Input Signal Monitor Allocation for CN1-12 (SVCMD_IO)

n.
X
0 to 7 The settings are the same as the CN1-13 allocations.
CN1-12 Input Signal Monitor Enable/Disable Selection

n.
X
0
Disable allocation for CN1-12 input signal monitor.
1
Enable allocation for CN1-12 input signal monitor.

n.
X
Reserved parameter (Do not change.)

n.X
Reserved parameter (Do not change.)
Setting
Setting
Default
Range
Unit
Setting
0000 to
0000
1717
0000 to
0000
1717
0000 to
0000
1717
Continued from previous page.
Applicable
When
Classi-
Motors
Enabled
fication
Immedi-
All
Setup
ately
Immedi-
All
Setup
ately
Immedi-
All
Setup
ately
Continued on next page.
Refer-
ence
*2
*2
*2

Advertisement

Table of Contents
loading

Table of Contents