Lenovo System x3550 M4 Installation And Service Manual page 99

Hide thumbs Also See for System x3550 M4:
Table of Contents

Advertisement

Figure 77. Operator information panel installation
Step 5.
Inside the server, connect the cable to the rear of the operator information panel assembly.The
following illustration shows the cable routing for the operator information panel.
Figure 78. Operator information panel cable connection
The following notes describe additional information when you install the cable:
• To connect the operator information panel cable on the system board, press evenly on the
cable. Pressing on one side of the cable might cause damage to the cable or connector.
• The operator information panel cable must pass through the chassis latch between fan 3 and fan
4 in order not to impede the fan cage.
Step 6.
Replace the cover (see "Replacing the cover" on page 195).
.