Lenovo System x3550 M4 Installation And Service Manual page 554

Hide thumbs Also See for System x3550 M4:
Table of Contents

Advertisement

Yes
Alert Category
Critical - Other
SNMP Trap ID
50
CIM Information
Prefix: PLAT ID: 0240
User Response
1. Check the system-event log.
2. Check the DIMM error LEDs.
3. Remove the failing DIMM from the system board.
4. Check for a server firmware update. Important: Some cluster solutions require specific code
levels or coordinated code updates. If the device is part of a cluster solution, verify that the latest
level of code is supported for the cluster solution before you update the code.
5. Make sure that the installed DIMMs are supported and configured correctly.
6. (Trained technician only) Replace the system board.
• 806f0813-2582ffff : A Uncorrectable Bus Error has occurred on system
[ComputerSystemElementName]. (PCIs)
This message is for the use case when an implementation has detected a Bus Uncorrectable Error.
May also be shown as 806f08132582ffff or 0x806f08132582ffff
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - Other
SNMP Trap ID
50
CIM Information
Prefix: PLAT ID: 0240
User Response
1. Check the system-event log.
2. Check the PCI LED.
3. Remove the adapter from the indicated PCI slot.
4. Check for a server firmware update. Important: Some cluster solutions require specific code
levels or coordinated code updates. If the device is part of a cluster solution, verify that the latest
level of code is supported for the cluster solution before you update the code.
5. (Trained technician only) Replace the system board.
• 806f0813-2584ffff : A Uncorrectable Bus Error has occurred on system
[ComputerSystemElementName]. (CPUs)
This message is for the use case when an implementation has detected a Bus Uncorrectable Error.
540
Lenovo System x3550 M4 Installation and Service Guide

Advertisement

Table of Contents
loading

This manual is also suitable for:

7914

Table of Contents