Diagnostic Tools - Lenovo System x3550 M4 Installation And Service Manual

Hide thumbs Also See for System x3550 M4:
Table of Contents

Advertisement

Step 1.
Is the server part of a cluster?
• No: Go to step 2.
• Yes: Shut down all failing servers that are related to the cluster. Go to step 2.
Step 2.
Complete the following steps:
a.
Check the power supply LEDs (see "Power-supply LEDs" on page 129).
b.
Turn off the server and all external devices.
c.
Check all internal and external devices for compatibility at
serverproven/
d.
Check all cables and power cords.
e.
Set all display controls to the middle positions.
f.
Turn on all external devices.
g.
Turn on the server. If the server does not start, see "Troubleshooting by symptom" on page
139.
h.
Check the system-error LED on the operator information panel. If it is lit, check the light path
diagnostics LEDs (see "Light path diagnostics" on page 121).
i.
Check for the following results:
• Successful completion of POST (see "POST" on page 136 for more information)
• Successful completion of startup, which is indicated by a readable display of the operating-
system desktop
Step 3.
Is there a readable image on the monitor screen?
• No: Find the failure symptom in "Troubleshooting by symptom" on page 139; if necessary, see
"Solving undetermined problems" on page 162.
• Yes: Run DSA (see "Running the DSA Preboot diagnostic programs" on page 137).
– If DSA reports an error, follow the instructions in Appendix C "DSA diagnostic test results" on
page 735.
– If DSA does not report an error but you still suspect a problem, see "Solving undetermined
problems" on page 162.

Diagnostic tools

The section introduces available tools to help you diagnose and solve hardware-related problems.
• Light path diagnostics
Use light path diagnostics to diagnose system errors quickly. See "Light path diagnostics" on page 121
for more information.
• Event logs
The event logs list the error codes and messages that are generated when an error is detected for the
subsystems IMM2, POST, DSA, and the server baseboard management controller. See "Event logs" on
page 133 for more information.
• Integrated management module II
The integrated management module II (IMM2) combines service processor functions, video controller, and
remote presence and blue-screen capture features in a single chip. The IMM provides advanced service-
processor control, monitoring, and alerting function. If an environmental condition exceeds a threshold or
if a system component fails, the IMM lights LEDs to help you diagnose the problem, records the error in
the IMM event log, and alerts you to the problem. Optionally, the IMM also provides a virtual presence
.
http://www.lenovo.com/
.
Chapter 4
Troubleshooting
119

Advertisement

Table of Contents
loading

This manual is also suitable for:

7914

Table of Contents