7. (Trained technician only) Replace the system board. (n = microprocessor number) One of the
CPUs :
• 806f020d-0400ffff : Failure Predicted on drive [StorageVolumeElementName] for array
[ComputerSystemElementName]. (Drive 0)
This message is for the use case when an implementation has detected an Array Failure is Predicted.
May also be shown as 806f020d0400ffff or 0x806f020d0400ffff
Severity
Warning
Serviceable
Yes
Automatically notify support
Yes
Alert Category
System - Predicted Failure
SNMP Trap ID
27
CIM Information
Prefix: PLAT ID: 0168
User Response
1. Run the hard disk drive diagnostic test on drive n.
2. Reseat the following components: a. Hard disk drive b. Cable from the system board to the
backplane.
3. Replace the following components one at a time, in the order shown, restarting the server each
time: a. Hard disk drive. b. Cable from the system board to the backplane. c. Hard disk drive
backplane. (n = hard disk drive number)
• 806f020d-0401ffff : Failure Predicted on drive [StorageVolumeElementName] for array
[ComputerSystemElementName]. (Drive 1)
This message is for the use case when an implementation has detected an Array Failure is Predicted.
May also be shown as 806f020d0401ffff or 0x806f020d0401ffff
Severity
Warning
Serviceable
Yes
Automatically notify support
Yes
Alert Category
System - Predicted Failure
SNMP Trap ID
27
CIM Information
Prefix: PLAT ID: 0168
User Response
1. Run the hard disk drive diagnostic test on drive n.
454