When you are installing the heat sink on the same microprocessor that it was removed from, make sure that
the following requirements are met:
• The thermal grease on the heat sink and microprocessor is not contaminated.
• Additional thermal grease is not added to the existing thermal grease on the heat sink and
microprocessor.
Notes:
• Read the safety information that begins on "Safety" on page v.
• Read the "Installation guidelines" on page 31.
• Read "Handling static-sensitive devices" on page 33.
To replace damaged or contaminated thermal grease on the microprocessor and heat sink, complete the
following steps:
Step 1.
Place the heat sink on a clean work surface.
Step 2.
Remove the cleaning pad from its package and unfold it completely.
Step 3.
Use the cleaning pad to wipe the thermal grease from the bottom of the heat sink.
Note: Make sure that all of the thermal grease is removed.
Step 4.
Use a clean area of the cleaning pad to wipe the thermal grease from the microprocessor; then,
dispose of the cleaning pad after all of the thermal grease is removed.
Step 5.
Use the thermal-grease syringe to place 9 uniformly spaced dots of 0.02 ml each on the top of the
microprocessor. The outermost dots must be within approximately 5 mm of the edge of the
microprocessor; this is to ensure uniform distribution of the grease.
Figure 232. Thermal grease distribution
Note: If the grease is properly applied, approximately half of the grease will remain in the syringe.
Figure 233. Syringe
Step 6.
Install the heat sink onto the microprocessor.
Removing the heat-sink retention module
Use this information to remove the heat-sink retention module.
296
Lenovo System x3550 M4 Installation and Service Guide
0.02 mL of thermal
Microprocessor
grease