Serviceable
No
Automatically notify support
No
Related links
IBM Support website
Latest level of DSA
Latest level of BMC/IMM
• 217-800-000 : HDD Test Aborted
HDD Test Aborted. The test was canceled.
Recoverable
No
Severity
Warning
Serviceable
Yes
Automatically notify support
No
User Response
Complete the following steps:
1. Check cable connections.
2. Rerun the test.
3. Verify that Hard drive supports self test and self test logging.
4. If the problem remains, contact your technical-support representative.
Related links
IBM Support website
Latest level of DSA
Latest level of BMC/IMM
• 217-900-000 : HDD Test Failed
HDD Test Failed. The hard drive self-test detected a failure.
Recoverable
No
Severity
Error
Serviceable
Yes
Automatically notify support
No
User Response
Complete the following steps:
1. Check cable connections.
2. Rerun the test.
3. Verify the firmware is at the latest level.
4. Rerun the test.