Prefix: PLAT ID: 0498
User Response
Check the server airflow. Make sure that nothing is blocking the air from coming into or preventing the
air from exiting the server.
• 80010b01-2c01ffff : Numeric sensor [NumericSensorElementName] going high (upper non-
recoverable) has asserted. (Mezz Card Temp)
This message is for the use case when an implementation has detected an Upper Non-recoverable sensor
going high has asserted.
May also be shown as 80010b012c01ffff or 0x80010b012c01ffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Temperature
SNMP Trap ID
0
CIM Information
Prefix: PLAT ID: 0498
User Response
Check the server airflow. Make sure that nothing is blocking the air from coming into or preventing the
air from exiting the server.
• 80010b01-2d01ffff : Numeric sensor [NumericSensorElementName] going high (upper non-
recoverable) has asserted. (PCH Temp)
This message is for the use case when an implementation has detected an Upper Non-recoverable sensor
going high has asserted.
May also be shown as 80010b012d01ffff or 0x80010b012d01ffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Temperature
SNMP Trap ID
0
CIM Information
Prefix: PLAT ID: 0498
User Response
Check the server airflow. Make sure that nothing is blocking the air from coming into or preventing the
air from exiting the server.
• 80030006-2101ffff : Sensor [SensorElementName] has deasserted. (Sig Verify Fail)
388
Lenovo System x3550 M4 Installation and Service Guide