Alert Category
Critical - Redundant Power Supply
SNMP Trap ID
9
CIM Information
Prefix: PLAT ID: 0802
User Response
1. Check the LEDs for both power supplies.
2. Follow the actions in Power-supply LEDs.
• 800b010a-1e81ffff : Redundancy Lost for [RedundancySetElementName] has asserted. (Fan Zone
1)
This message is for the use case when Redundancy Lost has asserted.
May also be shown as 800b010a1e81ffff or 0x800b010a1e81ffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Fan Failure
SNMP Trap ID
11
CIM Information
Prefix: PLAT ID: 0802
User Response
1. Make sure that the connectors on fan n are not damaged.
2. Make sure that the fan n connectors on the system board are not damaged.
3. Make sure that the fans are correctly installed.
4. Reseat the fans.
5. Replace the fans. (n = fan number)
• 800b010a-1e82ffff : Redundancy Lost for [RedundancySetElementName] has asserted. (Fan Zone
2)
This message is for the use case when Redundancy Lost has asserted.
May also be shown as 800b010a1e82ffff or 0x800b010a1e82ffff
Severity
Error
Serviceable
Yes