CIM Information
Prefix: PLAT ID: 0520
User Response
1. Check the IBM support site for service bulletins or firmware updates that apply to this GPT error.
2. Set the UEFI setting DISK GPT Recovery to Automatic.
3. Replace the corrupt disk.
• 8007010f-2582ffff : Sensor [SensorElementName] has transitioned from normal to non-critical
state. (I/O Resources)
This message is for the use case when an implementation has detected a Sensor transitioned to non-
critical from normal.
May also be shown as 8007010f2582ffff or 0x8007010f2582ffff
Severity
Warning
Serviceable
Yes
Automatically notify support
No
Alert Category
Warning - Other
SNMP Trap ID
60
CIM Information
Prefix: PLAT ID: 0520
User Response
Complete the following step to solve PCI I/O resource errors:
1. Go to F1 Setup-> System Settings-> Device and I/O ports-> PCI 64 bit Resource and choose
enable.
• 80070114-2201ffff : Sensor [SensorElementName] has transitioned from normal to non-critical
state. (TPM Phy Pres Set)
This message is for the use case when an implementation has detected a Sensor transitioned to non-
critical from normal.
May also be shown as 800701142201ffff or 0x800701142201ffff
Severity
Warning
Serviceable
Yes
Automatically notify support
No
Alert Category
Warning - Other
SNMP Trap ID
60
CIM Information
Prefix: PLAT ID: 0520
Appendix A. Integrated management module II (IMM2) error messages