Lenovo System x3550 M4 Installation And Service Manual page 437

Hide thumbs Also See for System x3550 M4:
Table of Contents

Advertisement

Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Temperature
SNMP Trap ID
0
CIM Information
Prefix: PLAT ID: 0036
User Response
1. Make sure that the fans are operating. There are no obstructions to the airflow (front and rear of
the server), the air baffles are in place and correctly installed, and the server cover is installed and
completely closed.
2. Make sure that the heat sink for microprocessor n is installed correctly.
3. (Trained technician only) Replace microprocessor n. (n = microprocessor number)
• 806f0107-0302ffff : An Over-Temperature Condition has been detected on
[ProcessorElementName]. (CPU 2)
This message is for the use case when an implementation has detected an Over-Temperature Condition
Detected for Processor.
May also be shown as 806f01070302ffff or 0x806f01070302ffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Temperature
SNMP Trap ID
0
CIM Information
Prefix: PLAT ID: 0036
User Response
1. Make sure that the fans are operating. There are no obstructions to the airflow (front and rear of
the server), the air baffles are in place and correctly installed, and the server cover is installed and
completely closed.
2. Make sure that the heat sink for microprocessor n is installed correctly.
3. (Trained technician only) Replace microprocessor n. (n = microprocessor number)
• 806f0108-0a01ffff : [PowerSupplyElementName] has Failed. (Power Supply 1)
This message is for the use case when an implementation has detected a Power Supply has failed.
May also be shown as 806f01080a01ffff or 0x806f01080a01ffff
Appendix A. Integrated management module II (IMM2) error messages
423