Solving Ethernet Controller Problems - Lenovo System x3550 M4 Installation And Service Manual

Hide thumbs Also See for System x3550 M4:
Table of Contents

Advertisement

Table 17. Components associated with power rail errors (continued)
Pwr rail error in the IMM event log
Pwr rail 5 error
Pwr rail 6 error
d.
Replace the identified component.
Step 5.
Remove the adapters and disconnect the cables and power cords to all internal and external
devices until the server is at the minimum configuration that is required for the server to start (see
"Power-supply LEDs" on page 129 for the minimum configuration).
Step 6.
Reconnect all power cords and turn on the server. If the server starts successfully, reseat the
adapters and devices one at a time until the problem is isolated.
If the server does not start from the minimum configuration, see "Power-supply LEDs" on page 129 to
replace the components in the minimum configuration one at a time until the problem is isolated.

Solving Ethernet controller problems

The method that you use to test the Ethernet controller depends on which operating system you are using.
See the operating-system documentation for information about Ethernet controllers, and see the Ethernet
controller device-driver readme file.
Try the following procedures:
Step 1.
Make sure that the correct device drivers, which come with the server are installed and that they
are at the latest level.
Step 2.
Make sure that the Ethernet cable is installed correctly.
• The cable must be securely attached at all connections. If the cable is attached but the problem
remains, try a different cable.
• If you set the Ethernet controller to operate at 100 Mbps, you must use Category 5 cabling.
• If you directly connect two servers (without a hub), or if you are not using a hub with X ports, use
a crossover cable. To determine whether a hub has an X port, check the port label. If the label
contains an X, the hub has an X port.
Step 3.
Determine whether the hub supports auto-negotiation. If it does not, try configuring the integrated
Ethernet controller manually to match the speed and duplex mode of the hub.
Step 4.
Check the Ethernet controller LEDs on the rear panel of the server. These LEDs indicate whether
there is a problem with the connector, cable, or hub.
Components
• DVD drive (if one is installed)
• Fan 3
• Fan 4
• Hard disk drives
• DIMMs 13 through 18
• Optional adapter (if one is installed) in PCI riser-card
assembly 2
• PCI riser-card assembly 2
• Dual-port network adapter (if one is installed)
• Fan 5
• Fan 6
• DIMMs 19 through 24
.
Chapter 4
Troubleshooting
161