Lenovo System x3550 M4 Installation And Service Manual page 400

Hide thumbs Also See for System x3550 M4:
Table of Contents

Advertisement

Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Temperature
SNMP Trap ID
0
CIM Information
Prefix: PLAT ID: 0498
User Response
Check the server airflow. Make sure that nothing is blocking the air from coming into or preventing the
air from exiting the server.
• 80010b01-1403ffff : Numeric sensor [NumericSensorElementName] going high (upper non-
recoverable) has asserted. (DIMM AB VR Temp)
This message is for the use case when an implementation has detected an Upper Non-recoverable sensor
going high has asserted.
May also be shown as 80010b011403ffff or 0x80010b011403ffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Temperature
SNMP Trap ID
0
CIM Information
Prefix: PLAT ID: 0498
User Response
Check the server airflow. Make sure that nothing is blocking the air from coming into or preventing the
air from exiting the server.
• 80010b01-1404ffff : Numeric sensor [NumericSensorElementName] going high (upper non-
recoverable) has asserted. (DIMM CD VR Temp)
This message is for the use case when an implementation has detected an Upper Non-recoverable sensor
going high has asserted.
May also be shown as 80010b011404ffff or 0x80010b011404ffff
Severity
Error
Serviceable
Yes
Automatically notify support
No