Table 1. Server features and specifications (continued)
• Temperature: 1°C to 60°C (33.8°F
to 140°F)
• Maximum altitude: 3,050 m
(10,000 ft)
• Relative humidity: 5% to 80%
• Maximum dew point: 29°C (84.2°F)
Shipment (non-operating):
• Temperature: -40°C to 60°C (-40°F
to 140°F)
• Maximum altitude: 10,700 m
(35,105 ft)
• Relative humidity: 5% to 100%
• Maximum dew point: 29°C (84.2°F)
EU Regulation 617/2013 Technical Documentation:
International Business Machines Corporation
New Orchard Road
Armonk, New York 10504
http://www.ibm.com/customersupport/
For more information on the energy efficiency program, go to
energy-star/index.html
Product Type:
Computer server
Year first manufactured:
2012
Internal/external power supply efficiency:
• http://www.plugloadsolutions.com/psu_reports/IBM_FSA011_550W_SO-301_Report.pdf
• http://www.plugloadsolutions.com/psu_reports/IBM_7001676-XXXX_550W_SO-458_Report.pdf
• http://www.plugloadsolutions.com/psu_reports/IBM_7001605-XXXX_750W_SO-258_Report.pdf
• http://www.plugloadsolutions.com/psu_reports/SO-299_IBM_DPS-750AB-1_750W_Report.pdf
• http://www.plugloadsolutions.com/psu_reports/IBM_DPS-750AB-14%20A_750W_SO-527_Report.
pdf
Maximum power (watts):
See Power supply.
Idle state power (watts):
219
Sleep mode power (watts):
Not applicable for servers.
Off mode power (watts):
17
Noise levels (the declared A-weighed sound power level of the computer):
8
Lenovo System x3550 M4 Installation and Service Guide
– Temperature: 10°C to 35°C
(50°F to 95°F)
– Altitude: 0 to 914.4 m (3,000
ft)
Size:
• 1U
• Height: 43 mm (1.7 inches)
• Depth: 734 mm (28.9 inches)
• Width: 429 mm (16.9 inches)
• Weight: approximately 16.4 kg
(36.16 lb) when fully configured
Acoustical noise emissions:
• Sound power, idling: 6.5 bels
maximum
• Sound power, operating: 6.5 bels
maximum
ISO 9296. Actual sound-pressure
levels in a given location might
exceed the average values
stated because of room
reflections and other nearby
noise sources. The noise
emission level stated in the
declared (upper limit) sound-
power level, in bels, for a random
sample of system.