Problems Resolved In Xcp 2052; Problems Resolved In Xcp 2051 - Fujitsu M10 Product Notes

Hide thumbs Also See for M10:
Table of Contents

Advertisement

Problems resolved in XCP 2052

The following table lists the problems resolved in XCP 2052.
Table 3-18     Problems resolved in XCP 2052
SPARC M10-
RTI No.
1
4
4S
RTIF2-
x
x
x
130827-001
RTIF2-
x
130903-004
RTIF2-
x
131004-004

Problems resolved in XCP 2051

The following table lists the problems resolved in XCP 2051.
Description
A timeout or connection failure may be
detected for the communication party
because XSCF packet reception is
delayed, delaying the response, due to a
defect in the XSCF-LAN hardware
settings.
If XSCF master/standby switchover takes
place when either the XSCF BB control
cable or the XSCF DUAL control cable is
not connected properly, the settings at
the master XSCF side may not be
properly carried on to the standby XSCF
and thus, it may not operate properly.
If the standby XSCF is restarted while the
XSCF BB control cable is either faulty or
not connected, it is started as the master
XSCF, so that there are two master XSCF
units in the system.
When there are two master XSCF units,
system operation cannot be guaranteed.
This state can be confirmed from the fact
that there are two chassis for which the
MASTER LED is lit on their rear panels.
Workaround
There is no effective workaround.
There is no effective workaround.
Please make sure that the XSCF BB
control cable and the XSCF DUAL
control cable is properly connected.
If this symptom occurs, confirm whether
each setting by master XSCF had been
stored after confirming that the cables are
properly connected. Set up XSCF again
when the setting has not been saved.
There is no effective workaround.
Do not reset an XSCF when the XSCF BB
control cable between the master and
standby is either faulty or not connected.
[How to restore]
If there are two master XSCF units in the
system, turn off all the chassis and then
turn them on again.