Table 3-6     Problems resolved in XCP 2240 (continue d)
SPARC M10-
RTINo.
1
4
4S
RTIF2-
x
141106-001
RTIF2-
x
141110-001
RTIF2-
x
x
x
141113-001
RTIF2-
x
x
x
141203-001
RTIF2-
x
x
x
141208-002
RTIF2-140711-001 additional information
This problem (RTIF2-140711-001) has been resolved for XCP 2240 and later versions.
However, the Oracle Solaris time may deviate if a physical partition is started up
immediately after updating the firmware from XCP 2232 or earlier to XCP 2240 or
later. To synchronize the time, see
Description
Any of the following errors related to
abnormal temperature may be
erroneously registered.
- Temperature out of range error
- High temperature at SW
In these error logs, the first two bytes of
the second field in [Code:] has the value
of "0013".
ldm(1M) may not display correct CPU
utilization and may not work the
dynamic resource management (DRM)
on large domain system where 150
domains or more exist.
Security fixes. (CVE-2014-3566)
For detail, see the Oracle website relating
to the following:
Critical Patch Updates
In some rare cases, "CPU Internal Serious
error" might occur.
After a "CPU fatal error" occurs, the time
required for a physical partition (PPAR)
restart may be 6 to 30 minutes longer
than usual. The required restart time
varies depending on the number of
mounted PCIe cards.
If many PCIe cards are mounted, the
following error may be mistakenly
detected.
- In the case of a SPARC M10-4S system
consisting of 2BB or more
"SRAM data error"
- In the case of a SPARC M10-1/M10-4
systemv>"Timeout of Reset Watch.
PPARID 0"
Workaround
There is no effective workaround.
Ignore this message because there is no
impact on system operation.
There is no effective workaround.
Update the XCP firmware to XCP 2240 or
later.
There is no effective workaround.
There is no effective workaround.
[How to restore]
- If "SRAM data error" has been detected
Replace the component at the
suspected location indicated by the
error log. After that, update the XCP
firmware to XCP 2240 or later.
- If "Timeout of Reset Watch. PPARID 0"
has been detected
Update the XCP firmware to XCP 2240
or later.
"Notes on the logical domain
Chapter 3 Information on Software
time."
89