Table 3-21     Problems resolved in versions prior to XCP 2050 (continued)
SPARC M10-
RTI No.
1
4
4S
RTIF2-
x
x
x
121113-009
RTIF2-
x
x
x
121113-011
RTIF2-
x
x
x
121113-014
RTIF2-
x
x
x
121113-018
RTIF2-
x
x
x
121113-019
RTIF2-
x
x
x
121113-021
RTIF2-
x
x
x
121113-022
RTIF2-
x
x
x
121113-023
RTIF2-
121113-028
Fujitsu M10/SPARC M10 Systems Product Notes for XCP Version 2240 ・ March 2015
146
Description
While XSCF is running, process down,
panic or watchdog timeout occurs, which
may cause XSCF not to be restarted after
XSCF reset.
If you execute the showsnmp(8)
command, the following message may
appear, which means that the snmp
daemon has been terminated.
Agent Status: Disabled
The error message "/etc/redhat-release
not found" appears while XSCF is starting.
When you replace an FRU with the
replacefru(8) command, the message
"configuration changed (...)" showing the
configuration change may be registered
more than once in the event log.
When the power supply of the physical
partition (PPAR) is disconnected
according to the power supply schedule,
"-" may be displayed as the cause (Cause)
in the power log.
If time cannot be read accurately due to a
failed clock in the XSCF board, an error
showing a clock failure may not be
recorded in the error log.
If the operation panel has failed or is not
connected, XSCF cannot be started.
If a CPU failure occurs while Hypervisor
is running, the physical partition (PPAR)
is reset more than once, and restarting of
the PPAR may take time.
Workaround
Confirm that XSCF is successfully started.
If it is not started, turn off the power of
the physical partition (PPAR), and then
disconnect the input power supply to the
system and back on again (AC OFF/ON).
When recycling the power supply to the
system, wait for 30 seconds or more to
turn on the input power supply after
disconnecting.
In case XSCF is not started even if
recycling the input power supply to the
system, replace the CPU memory unit
lower (CMUL) or the motherboard unit
(MBU).
Execute the showsnmp(8) command
again to confirm that the snmp daemon
is restarted.
If "Agent Status: Disabled" remains
displayed, execute the setsnmp enable
command to restart the snmp daemon.
Ignore this message.
Ignore the message that appears second
time and later.
There is no effective workaround.
There is no effective workaround.
If the following message appears when
you execute the poweron(8) command,
the clock in the XSCF board has failed.
Replace the XSCF board.
Poweron canceled due to invalid system
date and time.
Connect the operation panel. If the
operation panel has failed, replace it.
There is no effective workaround.