Table 3-21     Problems resolved in versions prior to XCP 2050 (continue d)
SPARC M10-
RTI No.
1
4
4S
RTIF2-
x
x
x
130212-002
RTIF2-
x
x
x
130212-003
RTIF2-
x
130215-001
RTIF2-
x
x
x
130215-002
RTIF2-
x
130219-001
RTIF2-
x
x
130219-005
Description
When you check the domain status by
using the showdomainstatus(8)
command from the XSCF after executing
the ldm add-spconfig command from
Oracle Solaris, "Host stopped" is
displayed for all domains, including the
control domain.
If you execute the testsb(8) command to a
system board (PSB) that is being
diagnosed by the testsb(8) or diagxbu(8)
command in a different session, the PSB
that is being diagnosed may enter an
abnormal state and become unavailable.
After the hardware initial diagnosis
detects a system board (PSB) error as
described in the following error log, the
PSB may not be degraded but the
physical partition (PPAR) may be reset
repeatedly.
Code: 40002000-003cff0000ff0000ff-
02000e000000000000000000
FRU: /BB#x
Msg: SB deconfigured (SB-SB access error)
Code: 40002000-003cff0000ff0000ff-
02000e010000000000000000
FRU: /BB#x
Msg: SB deconfigured (not running)
Even when policy is set to psb by the
setpcl(8) command, a unit of resource to
be degraded when an error occurs may
not be a system board but Field
Replaceable Unit (FRU).
The takeover IP address of an XSCF
cannot be specified as a value for
"IPAddress" or "SlaveAddress," which
can be set in the management file for a
power supply interlocking group.
If a failure occurs in a component in a
physical partition (PPAR), the status of
the PPAR in the SNMP MIB is not
updated.
Workaround
When you check the domain status by
using the showdomainstatus(8)
command from the XSCF after executing
the ldm add-spconfig command from
Oracle Solaris, "Host stopped" is
displayed for all domains, including the
control domain.
Confirm that the PWR of the PSB to be
diagnosed is "n" and that Test is not
"Testing" by using the showboards(8)
command before executing the testsb(8)
command.
If a PSB becomes unavailable, power off
the entire system and then power it on
again.
Disconnect the PSB where an error is
detected from the PPAR configuration by
using the deleteboard(8) command.
Disconnect the PSB where an error is
detected from the PPAR configuration by
using the deleteboard(8) command.
Specify the IP addresses of XSCF-LAN#0
and XSCF-LAN#1 of the master XSCF
and the standby XSCF for "IPAddress"
and "SlaveAddress," respectively.
There is no effective workaround.